SM1002 programmable safety controller
As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

(1) Redundancy

(2) Difference

(3) Self-detection



   How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.

SM-1002 programmable controller

1002.png

·Is a configurable safety controller, which supports the input of various safety product components.

·Maximum support for 10 groups of dual-loop inputs.

·4-channel semiconductor safety output, expandable output module

·Input and output fault indicator light

·Safety certification: PL e, Cat: 4



395181ccb7a771e30162f6415dc922a.pngProduct selection

product name

model

Safety input

Safe output

brand

Safety controller

SM-1002

10CH

4SO

LHS

explain

You can enter up to 10 sets of dual-channel security products.

Safety grating, emergency stop, safety door lock, reset, etc.

Official website programming software download connection.:http://lhsafety.com.cn/showinfo-257-118-0.html


395181ccb7a771e30162f6415dc922a.pngsafety performance

• Performance level (PL): PL e

• Security category (Cat.): Cat.4

• Mission time (TM): 20 years

• Diagnostic coverage (DC/DC avg): 99%

• Safety Integrity Level (SIL): SIL3

• Hardware Fault Margin (HFT): 1

• Safe Failure Score (SFF): 99%

• Probability of dangerous failure (PFH d): 1.78E-9/h

• Stop Category: 0/1

Complies with standard EN ISO13849

Complies with standard EN ISO13849

Complies with standard EN ISO13849

Complies with standard EN ISO13849

Conforms to standards IEC61508, IEC62061

Conforms to standards IEC61508, IEC62061

Conforms to standards IEC61508, IEC62061

Conforms to standards IEC61508, IEC62061

Complies with standard EN 60204-1

395181ccb7a771e30162f6415dc922a.pngMain technical parameters

Power supply characteristics

·Power supply voltage: 24VDC

·Voltage range: 20~30VDC

·Current loss: ≤35mA(24VDC)

Input characteristics

·Input current: ≤10mA(24VDC)

·Conductor resistance: ≤15Ω

·Input equipment: emergency stop button, safety door, two-hand button, safety light curtain,

                   Heartbeat sensor, etc

·Input channel: 10

Relay output characteristics

·Number of contacts: 4SO (safety output)

·Contact fuse protection: 5A is fast, 3A is slow.

·Switching capacity: 2A/24VDC

Semiconductor output characteristics

·Number of contacts: 4SO (safety output)

·Contact fuse protection: 10A is fast, 6A is slow.

·Switching capacity: 2A/24VDC

Time characteristic

·Suction buffer time: ≤100ms

·Release buffer time: ≤30ms

·Recovery time:

         Emergency stop operation: ≤30ms

         Power failure: ≤1000ms

·Short-term power interruption: 20ms

control logic

·Control logic: 10 kinds of logic, and new logic can be customized according to customer requirements.

·Delay setting time: 0s~99s

·Heartbeat monitoring frequency: 0.1Hz~10Hz

·Frequency output logic block: 0.1Hz~10Hz


395181ccb7a771e30162f6415dc922a.pngEnvironmental characteristic parameters

·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

·Vibration frequency: 10Hz~55Hz

·Vibration amplitude: 0.35mm

·Operating temperature: -20℃~+60℃

·Storage temperature: -40℃~+85℃

·Relative humidity: 10%~90%

·Overvoltage grade: Ⅲ

·Pollution level: 2

·Altitude: ≤2000m

·Electrical clearance and creepage distance: in accordance with EN60947-1.

1002.png


395181ccb7a771e30162f6415dc922a.pngFunctional application parameters

功能框图

典型应用

图片3.png

30d4fa1676811c3a6977a8358764a55.png


输入元件:CH1(急停按钮);CH2(急停按钮);

               CH3 (急停按钮)

输入元件:CH7(急停按钮);CH8(急停按钮)

               CH10(复位按钮)

控制逻辑:CH1&CH2&CH3      

复位方式:手动复位   输出延时:0s

安全等级:Cat.4     性能等级:PLe    

安全完整性等级:SIL3


395181ccb7a771e30162f6415dc922a.png

Wiring diagram

Power Supply 

1.png

input

2.png3.png4.png
5.png6.png7.png
8.png9.png

reset

10.png11.png

feedback

12.png13.png

output

14.png15.png


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright © Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh