NL 200 series obstacle avoidance laser scanner

扫描仪.png

·Continuous and constant light source based on pulse laser ranging technology

·The magnitude of pulsed light energy should be 1000 times higher to ensure the stability and reliability of measurement. At the same time, combined with nanosecond narrow pulse technology, a class of laser products is ensured to be safe for human eyes

·Wide dynamic range echo signal processing technology can accurately detect objects with arbitrary reflectivity and position in the range, and realize stability in any complex and dynamic environment and consistency among lidar products

·The imported scanning motor is preferred, the noise is lower than 30 decibels, which is more stable and quieter

·Ip65 protection design, special temperature drift error elimination design, professional EMC design, professional

·Anti-light interference design to adapt to more complex industrial environments

·The detachable window design facilitates maintenance and reduces maintenance cost

Product specification

product name

Maximum detection range

Detection accuracy

Scanning angle

output form

NL201-1070P

10m@70%reflectivity

±3cm@1sigma

270°

PNP

NL201-0670P

6m@70%reflectivity

±3cm@1sigma

270°

PNP

NL201-0410N

2m@70%reflectivity

±3cm@1sigma

270°

NPN

NL201-0210N

2m@70%reflectivity

±3cm@1sigma

270°

NPN

Installation mode

Horizontal installation

deploy

DB 9adapter andUSB turnRS232 Serial Line

Power cord

5M give/present as a gift

Programming line

give/present as a gift

explain


Laser scanner main body
Floor mounting bracket
Power cord
Programming line

图片.png

转接头.png

 

USB 转RS232 串口线.png

96160.png


technical parameter

optical characteristics

Laser light source

Wavelength 905nm, a kind of laser products.

Maximum detection range

Radius 10m@70%% reflectivity (white object)

Radius 4m @ 10% reflectivity (black object)

Scanning angle range

270°

Angular resolution

0.5°

Scanning angle range

±3cm

Electrical/mechanical parameters

operating voltage

DC9V~DC30V

Power-on start time

typical value8

power consumption

3W(typical value)

output

OUTPUT1:defence area1 Enter the OFF state when an obstacle is detected.

OUTPUT2:defence area2 Enter the OFF state when an obstacle is detected.

OUTPUT3:defence area3 Obstacle/system failure detected

(optional, configurable), enter the OFF state.

outline dimension

62mm×64mm×83m

Cable length

The standard line length is 1m, and the longest is ≤30m.

Environmental characteristics

ambient temperature

Work:-10℃ ~ 50℃ (no frost and fog)

Storage:-40℃ ~ 70℃

ambient humidity

work:35%RH~85%RH

save:35%RH~95%RH

Anti-light interference

15000Lux

resist the impact

Acceleration 10g;; Pulse duration: 16ms;;

Collision times: three axes, each axis is 1000 10 times.

Vibration resistance

Frequency 10 Hz ~ 55 Hz; Amplitude: 0.35±0.05mm;;

Scanning times: three axes, 20 times per axis.

the protection grades

IP65

electromagnetic compatibility


Sex (EMC)


EMI

EN61326-1:2013

EN55011:2009+A1:2010

EMS

EN61326-1:2013

EN61000-4-2:2009

EN61000-4-3:2006+A1:2008+A2:2010

EN61000-4-4:2004+A1:2010

EN61000-4-6:2009

EN61000-4-8:2010

EN61000-4-11:2004

Configurable function

Sector configuration

Users can configure the LSE sector into the required shape through the configuration software.

Response time

Adjustable (36ms/ lap)

Zone group switching

Four groups of external input signals (Z1, Z2, Z3 and Z4) realize the switching of 16 zone groups, and the zone group 15 works when Z1, Z2, Z3 and Z4 are not connected by default.

work pattern

NL200 series provides four working modes, and the default working mode is 4.


technical parameter
防护区域.png

sign

meaning

describe

3

User-configured sector3

Obstacle detected 时OUTPUT3 enter OFFcondition

2

User-configured sector2

Obstacle detected OUTPUT2 enter OFF condition

1

User-configured sector1

Obstacle detected OUTPUT1 enter OFF condition

NL200series

laser radar

Scanning angle 270, radius 10m @ 70% reflectivity, radius 4m @ 10% reflectivity.


Product dimension diagram

尺寸图.png


hookup

NPN接线方式.png

PNP wiring diagram:


The yellow line is the user TXD end and the radar RXD end;


The green line is the user RXD end and the radar TXD end.


PNP接线方式.png

NPN wiring diagram:


The yellow line is the user TXD end and the radar RXD end;


The green line is the user RXD end and the radar TXD end.



Installation mode

安装方式.png


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright © Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh