Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首页 > Home > Safety products > Safety Relays 安全控制器 > safety relay
SM602-5501 speed monitoring safety relay

1720075279779242.png

·It is a speed monitoring safety relay with Modbus communication function.

·Support proximity switch, encoder input and safety sensor input.

·2-way relay safety output

·4-channel semiconductor safety output

·Configuration software can be used to set safety control logic.

·Safety certification: PL e, Cat: 4



Product selection

product name

model

Safety input

Safe output

brand

Safety controller

SM602-5501

3CH

2NO+4SO

LHS

explain

Proximity switch, encoder input, safety sensor


safety performance

·Performance level (PL): PLE

·Safety category (cat.): cat.4.

·Task time (TM): 20 years.

·Diagnostic coverage (DC/DC AVG): 99%

·Safety integrity level (SIL): SIL3

·Hardware fault margin (HFT): 1

·Safety Failure Score (SFF): 99%

·PFHD: 1.78e-9/h

·Stop category: 0/1

·Meet the standard ENISO13849.

·Meet the standard ENISO13849.

·Meet the standard ENISO13849.

·Meet the standard ENISO13849.

·Comply with standards IEC 61508 and IEC 62061.

·Comply with standards IEC 61508 and IEC 62061.

·Comply with standards IEC 61508 and IEC 62061.

·Comply with standards IEC 61508 and IEC 62061.

·Comply with standard EN60204-1.


Main technical parameters

Power supply characteristics

·Power supply voltage: 24VDC

·Voltage range: 20~30VDC

·Current loss: ≤120mA(24VDC)

Input characteristics

·Input current: ≤10mA(24VDC)

·Conductor resistance: ≤15Ω

·Input equipment: PNP proximity switch, TTL/ sine and cosine encoder, switch-type safety element.

·Input channel: 6

·Input frequency: input frequency: 0.01Hz~2KHz for proximity switch and 0.01Hz~300KHz for encoder.

Relay output characteristics

·Number of contacts: 2NO (safety output)

·Contact material: AgSnO2

·Contact fuse protection: 10A is fast, 6A is slow.

·Switching capacity: 5A/230VAC;; 5A/24VDC

Semiconductor output characteristics

·Number of contacts: 4SO (safety output)

·Contact fuse protection: 5A is fast and 3A is slow.

·Switching capacity: 5A/24V DC

Time characteristic

·Suction buffer time: ≤100ms

·Release buffer time: ≤30ms

·Recovery time:

 Power failure: ≤1000ms

·Short interruption of power supply: 20ms

Communication characteristics

·Baud rate: 38.4kbps (fixed)

·Communication length: ≤1000m

·Networking capacity: ≤10 units


Environmental characteristic parameters

·Electromagnetic compatibility: comply with EN 60947, EN 61000-6-2 and EN 61000-6-4.

·Vibration frequency: 10Hz~55Hz

·Vibration amplitude: 0.35mm

·Operating temperature: -20℃~+60℃

·Storage temperature: -40℃~+85℃

·Relative humidity: 10%~90%

·Overvoltage grade: Ⅲ

·ollution level: 2

·Altitude: ≤2000m

·Rated isolation voltage: 250V AC.

·Rated impulse voltage: 6000V(1.2/50us)

·Insulation strength: 1500V AC, 1min.

·Electrical clearance and creepage distance: in accordance with EN60947-1.

1720075788298375.png


Functional application parameters

functional block diagram

Typical application

1720075999380347.png

9c1bd698f83830e34e0f8ee0e37b84f.png


Functional application parameters

Overall dimensions (depth× height× width): 114.5mm×99.0mm×45.0mm Product net weight: 260g.

1720076132876086.png


Wiring diagram

Power 

Supply 

1713317657777136.png

input

1720078649796498.png

input

1720078988272634.png1720079009396995.png1720079029950557.png
1720079153908472.png1720079171359866.png1720079187368340.png
1720079234352738.png1720079256909808.png1720079273946995.png

reset

1720079458629580.png1720079486817303.png

feedback

1720079689941378.png1720079638927268.png

output

1720079619730539.png1720079602220638.png1720079564699354.png


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright © Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh