Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首页 > Home > Safety products > Safety Relays 安全控制器 > safety relay
SM-C-101 series safety relay
1734595036860417.png

·Universal shell: 22.5mm universal shell, with strong versatility in appearance and size.

·Three-proof paint coating of circuit board: protect the circuit board from moisture, insulation, water, dust and parts loosening to meet G3 anti-corrosion standard.

· Convenient wiring: the power supply is represented by red and black, the input terminal is represented by S plus number, and the input terminal is represented by number.

·All-localization: All-localization devices are adopted, with high cost performance and worry-free quality.

·Support a variety of equipment input: emergency stop button, safety door, PNP safety light curtain, expansion module.


Product selection1588126326899852副本.png  image.png

picture

1734593063765486.png1734593017534425.png

name

SM-C-101 series safety relay

SM-C-101 series safety relay

model

SM-C-101 3A1B

SM-C-101 3A1B.C

Power supply characteristics

supply voltage

24V DC / AC

Voltage tolerance

0.85 ~ 1.1

Ac frequency

50Hz~60Hz

voltage range

20~30V DC

Current loss

≤90mA (24V DC)

≤90mA (24V DC); ≤240mA (24V AC)

Input feature

incoming current

≤50mA (24V DC)

conductor resistance

≤15Ω

input device

Emergency stop button, safety door, PNP safety light curtain

Output characteristics

Number of contacts

3NO + 1NC

Contact material

AgSnO2 + 0.2μm Au

Safe output

13, 14, 23, 24, 33, 34, 41, 42

Auxiliary output

CH1,CH2 (status indication)

Contact type

Forced orientation

Output characteristics

Contact fuse protection

10AgL/gG, NEO ZED (normally open contact)

6AgL/gG, NEO ZED (normally closed contact)

Electric shock mechanical life

More than 107 times

Switching capacity (EN60947-5-1)

AC-15,5A/230V;DC-13,5A/24V

Time characteristics

Suction buffer time

Emergency stop operation: ≤30ms

Power failure: ≤100ms

≤300ms

Release buffer time

-

≤30ms

recovery time

Emergency stop operation: ≤30ms

Power failure: ≤100ms

≤100ms

Short-term interruption of power supply

-

20ms

Environmental characteristics

electromagnetic compatibility

EN 60947, EN 61000-6-2, EN 61000-6-4

frequency of oscillation

10Hz~55Hz

Vibration amplitude

0.35mm

usage temperature

-20℃~+60℃

storage temperature

-40℃~+85℃

relative humidity

10%~90%

altitude

≤2000m

Insulation characteristics

Overvoltage grade

class of pollution

2

rated insulation voltage

250V AC

Rated impulse voltage

6000V (1.2/50us)

dielectric strength

1500V AC, 1min

Electrical clearance and creepage distance

Comply with EN 60947-1.

authentication

safety integrity level

SIL3

Performance grade

PLe

Security category

Cat.4

explain

1. The internal strong conductance with. c and without. c is different.

2. The terminal with. c and socket are integrated and unpluggable, while the terminal without. c and socket are separated.


Functional block diagram/typical application

model

 SM-C-101 3A1B

 SM-C-101 3A1B.C

functional block diagram1734593546117716.png1730256101582681.png
Typical application

1734594133783688.png


Dual channel emergency stop button input     

Inter-channel short circuit monitoring          

manual reset                  

Feedback with output contact             

Applicable to the highest security level 4.  

S1:Double channel emergency stop button  

S3:Reset button

K7, K8: Contactor

F1: External fuse protection

M1: Motor

1731465880682417.png

1731465969116462.png



Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright © Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh